Corbin Russwin ED5800 & ED5800A Fire Concealed Vertical Rod Exit Device
Corbin Russwin ED5800 & ED5800A Fire Concealed Vertical Rod Exit Device 630 finish
Handing: Device is handed but easily field reversible. Lever trim is handed.
Bar length: Easily field cut to size. Standard: 36" (914mm) bar fits 30"- 36" (762mm-914mm) door.
Finish: 630-Satin Stainless Steel
Door Thickness: 1-3/4" (44mm) standard
Stile: Minimum width 4-1/2" (114mm).
Door Height: Standard: top rod for 8' door.
Latchbolt: Top: 3/4" (19mm) throw, stainless steel pullman-type with automatic deadlatching. Bottom: 5/8" (16mm) throw deadbolt, held retracted during door swing.
Vertical Rods: 1/2" O.D. tubing, electroplated for corrosion resistance.
Materials: Heavy-duty cold-forged steel chassis; heavygauge steel mechanisms, electroplated for corrosion resistance; finished parts are brass, bronze or stainless steel; stainless steel springs; nylon bearings.
Projection: 3-1/4" (83mm) active
Dogging: Standard on panic devices; single-point 1/4 turn hex key dogging.
Fasteners: Standard on panic devices: machine screws. Standard on fire-rated devices: sex nuts and bolts.
Strike: Top: roller type. Bottom: flush mounted.
Applications and Listings: For use on metal doors only
Warranty: Five-year limited.
Certification/Compliance ANSI Meets A156.3, Type 8, Grade 1. Meets A117.1 Accessibility Code. UL/cUL All devices listed for safety as panic hardware; devices comply with UL 305 standards for panic hardware. Three-hour fire-rated devices listed as fire exit hardware for A label and lesser class 8' x 8' double doors; UL symbol on active case cover indicates listing. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin, Inc. makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. California State Reference Code This product has been approved by the California State Fire Marshal pursuant to section 13144.1 of the California Health and Safety Code. NFPA All exit devices comply with NFPA 101 Life Safety Code. All fire-rated devices comply with NFPA 80 Fire Doors and Windows. ADA Exit devices, lever trims and pulls comply with Americans with Disabilities Act.