- PS-EXIT Catalog Page
- PS-EXIT Sell Sheet
- Installation Instructions & Templates
- 8000/3000 Exit Device Overview Brochure (Power Supplies included)
The PS-EXIT Power Supply is specifically designed to protect and optimize the performance of Adams Rite 8000/3000 Series exit devices with Motorized Latch Retraction (MLR) or Electric Latch Retraction (LR) options by delivering filtered and regulated power.
Function:
This power supply is designed to provide power and control for up to two MLR or LR exit devices. Each exit device is controlled by a timer that is initiated by a switch closure. The timer is user-configured and holds the exit device(s) in the unlatched position for 2 – 60 seconds. At the end of the selected time, the exit device(s) will re-latch. If the switch controlling the exit device is closed longer than the selected time, the exit device remains unlatched until the controlling switch is released.
- An optional mode is available that allows both retraction timers to activate in response to a closure of either switch.
- Exit devices under access system control remain latched during a complete power failure but always allow free mechanical egress
Certifications:
- UL 294
- CAN/CSA-C22.2 No. 223
Features:
Housing: Hinged, steel cabinet measures 10" x10-3/8" x 4-1/8" [254 mm x 263.5 mm x104.8 mm]. Blue, baked enamel finish with knockouts for conduit connections. Sized to accommodate two sealed, lead acid batteries (7AH, not included).
Timer: Initiated by switch closure to control each exit device. Timer is user-configured and holds exit device in unlatched position for 2 - 60 seconds. At end of selected time, exit device will relatch.
Operating Modes: The PS-EXIT is designed to power up to two 8000/3000 MLR or LR exit devices in the following operating modes:
- Single Input (Sequential Operation): either input retracts the corresponding exit device followed by retraction of second device. Control double-door exit with one input.
- Dual Input (Independent Operation): Each exit device is controlled by its own input switch. Control two separate exits with two inputs.
Shipping Weight: 10 lbs [4.5 kg]
Electrical:
Input Power: 115 VAC
Rated Output Current: Up to 0.8A per channel continuous rated output current
Typical Output Voltage:
- 24 - 26 VDC
- Up to 17 A pull-in current
Options
Battery Charger Kit (BBK-EXIT) is available separately to add battery backup capability to the PS-EXIT. The enclosure is sized to accommodate two 12 Vt – 7AH sealed, lead acid batteries (not included).
Product Note: Adams Rite recommends that for optimal performance all exit devices with the MLR or LR options are installed and powered using PS-EXIT power supplies. Failure to do so may cause permanent damage to the exit device.
Related Products: When purchasing this product, please consider the following related products, available separately:
Accessories | Power |
BBK-EXIT Battery Backup Kit available separately. | 4612 Power Transfer Device, 4605 Transformer, 4603 Rectifier |
Compatible Products: This product is compatible with the following products:
Exit Devices |
8000 Series electrified exit devices with MLR or LR option |