SDC S6300-DES Series Slaved Delay Egress Mortise Exit Device - Fire Rated
SKU: S6303FRRU36DESEE
$ 1,424.50
SDC S6300-DES Series Slave Delayed Egress Mortise Exit Devices
The SDC S6300-DES Series Slave Delayed Egress Mortise Exit Devices are designed to secure doors as part of an ExitCheck® delayed egress system. These slave-operated mortise exit devices work with an SDC 101-DE Series Delayed Egress Controller to provide controlled delayed egress for commercial, institutional, healthcare, and other security-sensitive applications.
When the push pad is depressed, the S6300-DES sends a trigger input to the 101-DE controller. The controller then initiates the selected 15- or 30-second delayed egress cycle, providing time for authorized personnel to respond while maintaining controlled access through the opening.
Available in configurations for both panic and fire-rated applications, the S6300-DES Series provides a clean, integrated solution for delayed egress doors.
Important: S6300-DES slave operating exit devices do not function independently. They must be ordered and installed with an SDC 101-DE Series Delayed Egress Controller.
Key Features
Designed for ExitCheck® delayed egress systems
Slave operating mortise exit device
Available for panic-rated and fire-rated applications
Push pad activation provides the delayed egress trigger
Supports 15- or 30-second delayed egress cycles when used with the 101-DE controller
Low power consumption
Energy-saving design
Voltage and current spike protection
Compatible with access control system integration
Available configurations for different door and security requirements
Optional Features
Customize the S6300-DES to meet specific access control and monitoring requirements:
Request-to-Exit (REX) monitoring
Latch Status (LS) monitoring
Electrified case with fail-secure outside lever
Electrified case with fail-safe outside lever
Applications
The S6300-DES Series is well suited for:
Healthcare facilities
Commercial buildings
Institutional facilities
Educational facilities
Security-sensitive areas
Delayed egress doors
Panic and fire-rated exit applications
Access-controlled exit openings
System Compatibility
The S6300-DES Series requires an SDC 101-DE Series Delayed Egress Controller for operation. The controller supplies the delayed egress functionality, while the S6300-DES slave exit device secures and monitors the door as part of the complete system.
Pair the SDC S6300-DES Slave Delayed Egress Mortise Exit Device with an SDC 101-DE controller for a complete, code-conscious delayed egress solution.
DESCRIPTION TAG: The S6300-DES Series requires an SDC 101-DE Series Delayed Egress Controller for operation. The controller supplies the delayed egress functionality, while the S6300-DES slave exit device secures and monitors the door as part of the complete system.