Dorma DS4670-01A - Overhead Concealed Swing, Push Side Top Jamb Mount, With 2 910TC Wave Plate Actuators, Painted Aluminum AL (689)
Dorma DS4670-01B - Overhead Concealed Swing, Push Side Top Jamb Mount, With 2 910TC Wave Plate Actuators, Painted Dark Bronze DB (695)
Dorma DS4670-02A - Overhead Concealed Swing, Pull Side Top Jamb Mount, With 2 910TC Wave Plate Actuators, Painted Aluminum AL (689)
Dorma DS4670-02B - Overhead Concealed Swing, Pull Side Top Jamb Mount, With 2 910TC Wave Plate Actuators, Painted Dark Bronze DB (695)
Low Energy Operator
The ED50 low energy swing door operator is the perfect solution for barrier-free access applications, offering a true manual door closer experience. Simple and easy to install, the ED50 provides many features and functions to make existing doors easily accessible.
This medium-duty swing door operator can automate new or existing swing doors with a push plate, wave plate, or other "knowing act" device. The ED50 combines advanced automatic power assist, minimal push forces (as low as ANSI size 1) and reliable closing. Outswing or inswing doors can be adapted for barrier-free access with push, pull, or deep reveal arms suited to a wide variety of door hanging options.
Operator Types and Configurations:
- Surface applied
- Overhead concealed
- Surface applied
Configuration:
- 4" x 6" x length as required (Narrow)
- 2-3/4" x 5-1/8" x length as required (Fine)
- 26.5 lb
- 24 volts DC ± 5% 1.5 A
- 110° (door stop recommended)
- 16 AWG
- 220 lb at 48" door width
- Minimum 28"
- Maximum 48"
- 13/16" (20 mm)
- 1-3/16" (30 mm)
- 2-3/8" (60 mm)
- 1-3/16" (30 mm)
- 2-1/4"
- 0 to 9-3/4"
- 8" to 19-3/4"
Required operating conditions:
- 5°F to 122°F
- Relative air humidity
- Maximum 93%, non-condensing
- 115 volts AC ± 10%, 50/60 HzMaximum 6.6 A
- Maximum 15 Amps,dedicated branch circuit
- NEMA 1
- Maximum 12 AWG
- Maximum 50 db(A)
Inputs:
- X4*
- Interior, exterior
- Normally open contact
- X5
- Swing, approach sides, normally closed contact
- X10 - 57, 57a
- 8 to 24 volts DC/volts AC + 5%
- X1 - 35, 3
- d2 - parameter
- Configure for Normally Open or Normally Closed
- X6 - 4, 4a
- d1 - parameter
- Configure for Normally Open or Normally Closed
Door closer modes:
- Door opens automatically following pulse generation by a knowing act device or by push/pull.
- Designed for doors primarily accessed manually.
- Available only in door closer mode, manual opening drive support is automatically adjusted to operator size.
Hold open time:
- dd - parameter
- 0 to 30 seconds
- dn - parameter
- 0 to 30 seconds
- do - parameter
- 0 to 30 seconds
- hd - parameter
- Automatic, manual door modes
- Ud - parameter
- 0 to 4 seconds
Integrated functions:
- Fo - parameter
- Minimum 20 lbf (4.5)
- Maximum 60 lbf (13.5.5)
- Fc - parameter
- Minimum 20 lbf (4.5)
- Maximum 60 lbf (13.5.5)
- 27° per second
- May be limited by door weight after learning cycle.
- 27°per second
- May be limited by door weight after learning cycle.
- X7 - 97, 98, 99
- Sr - parameter
- Door closed - Common
- Door open - Normally Open
- Door closed, locked - Normally Closed
- X3 - 43,3
- Motor lock
- Fo, Fc - parameters
- 2.5 lb f100 N
- Adjustable with potentiometer
- Green - 24 Vdc power
- Red - Error codes
- Yellow - Service interval
- Auto, Close, Open, Exit Only; Off, On
- 4-button keypad, 2-digit display
- Overload protection
- Driving phase optimization
- CC - parameter
- 0 to 1,000,000
- hA, hF, hS - parameters
- Drive support for manual opening door
- PG - parameter
- Auto opening of door at 4° open