Command Access PD15/PD16 Storefront Exit Device, Rim and CVR (Jackson 1200, Kawneer 1686/1786 & AHT Retrofit)
The Command Access PD15/16 is a complete retrofit storefront exit device series for Kawneer 1686/1786, Jackson 1285/1295 and AHT 8000/9000. PD15-M is motorized latch pullback; PD16 is mechanical. Existing vertical rods can be reused with no additional prep.
How It Works
- PD15-M: motorized latch retraction with electric dogging rated for continuous duty; auto re-engages if pulled from the dogged position.
Features
- PTS electronic adjustment (about 5 seconds, approx. 1/4")
- MM4 Smart Module with on-board diagnostics
- 8' Quick Connect cable
- Slim low profile design for narrow stile doors
- Fits narrow, medium and wide stile aluminum doors
Specifications
| Voltage | 24 VDC only; shuts down above 28 VDC |
| Current | Standard: average peak 1.3 A, hold 170 mA |
| Wire run | Up to 300 ft with 2-18 gauge |
| Door | 1-3/4" aluminum, minimum 2" stile |
| Handing | RIM non-handed; CVR handed (LHR/RHR) |
| Fail mode | Fail secure (EU) |
| Warranty | 3-year "no hassle" |
Choices Made at Checkout
Picked in the product options under the variant choices. Price adds are shown next to each choice.
| Handing (CVR only) | Not needed (RIM); LHR; RHR |
| Options | None; REX request to exit switch (+$64.58); Extended rods (+$56.51) |
What is Included
- Complete exit device; fasteners provided
- Cylinder not included (rim cylinder by others)
Frequently Asked Questions
Q: Do CVR models need a hand?
A: Yes. Choose LHR or RHR at checkout for CVR devices.
Q: Can 48" be cut down?
A: Command Access says 48" device mechanics can be cut down to 42" in the field.
Source: Command Access Technologies price list (May 19, 2025, revised Nov 2025), commandaccess.com product pages, and Command Access cut sheets and installation instructions. Command Access is not affiliated with the other brands named here; brand names show compatibility only. Please check voltage, fail safe or fail secure, door prep and handing before ordering.