Fasteners: 12-24 X 3/4" undercut self drilling, thread-forming tek machine screws for frame and 1/4-20 sex bolts and shoulder bolts for door
Standard Lengths: 79", 83", 85", 95" and 120" + Custom Sizes Available
Fire Rating:
Approved for use on metal swinging type fire doors rated up to and including 90 minutes (Specifiy "FR" option for 3 hour rating)
Approved for use on wood swinging type fire doors rated up to and including 60 minutes (Specifiy "FR" option for 90 minute rating)
Reinforcement:
Door Side: Not required for door weight up to 200 lbs. ABH recommends a minimum 12 gauge plate/channel for heavier doors.
Frame Side: Not required for door weight up to 200 lbs. For doors more than 200 lbs., a 16 gauge channel is recommended.
"PT" Electrical Power Transfer Prep (Specify Electrical Power Transfer Model, Location & Handing
"FR" Fire Studs
"WEDGE-HS" Adjustable Safety Wedge for Half Surface Models
"LR-BEAR" Ligature-Resistant Bearings
"DD" Dutch Door Prep
"SEC" Fasteners
"CUT" Cut to Custom Length
"TR" Tamper-Resistant (Hospital Tip, Every Other Bearing has a Set Screw) & Security Fasteners (Specify Door & Frame Material)
"TR-AHT-FS" Tamper-Resistant (Advanced Hospital Tip, Every Other Bearing has a Set Screw) & Security Fasteners (Specify Door & Frame Material) for Half/Full Surface
"SC" School Cap
"SPLICE" Spliced Hinge
"LL" Lead-Lined Cover (Half Surface & Full Surface - Door Leaf Only)