{"title":"Altronix","description":"","products":[{"product_id":"altronix-pt724a-timer-board","title":"Altronix PT724A Timer Board","description":"\u003cdiv class=\"section-header\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-8 col-md-10 text-left\"\u003e\n\u003ch1 class=\"dark-text\"\u003ePT724A\u003c\/h1\u003e\n\u003ch6 class=\"dark-text\"\u003eTimer, 365 Day 24 Hour Annual Event, 1 Channel, LCD Display, Battery Charger, Board\u003c\/h6\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"brand-logo\" class=\"col-sm-4 col-md-2\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row overview\"\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cdiv class=\"well\"\u003e\n\u003cp class=\"text-left\"\u003ePT724A is an extremely versatile 24 Hour 365 Day Event Timers designed to support a wide range of applications: Home and Building Automation, Security, Access Control, Lighting Control, Etc. The PT724A are equipped with an independently controlled form \"C\" relay contact that provides many latching and\/or momentary operations during a program schedule of your choice. Events may be set for single or multiple operations on a daily and\/or weekly schedule.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-container\" class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cul id=\"prod-tabs\" role=\"tablist\" class=\"nav nav-tabs\"\u003e\n\u003cli class=\"active\" role=\"presentation\"\u003e\u003ca data-toggle=\"tab\" role=\"tab\" aria-controls=\"specs\" href=\"https:\/\/www.altronix.com\/products\/PT724A#specs\"\u003eSpecifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e\u003ca data-toggle=\"tab\" role=\"tab\" aria-controls=\"dimensions\" href=\"https:\/\/www.altronix.com\/products\/PT724A#dimensions\"\u003eDimensions \u0026amp; Weight\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e\u003ca data-toggle=\"tab\" role=\"tab\" aria-controls=\"files\" href=\"https:\/\/www.altronix.com\/products\/PT724A#files\"\u003e\u003ci class=\"icon-fontawesome-webfont-230\"\u003e\u003c\/i\u003e\u003cspan\u003e \u003c\/span\u003eDocumentation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv id=\"prod-tabs-content\" class=\"tab-content text-left\"\u003e\n\u003cdiv id=\"specs\" class=\"tab-pane active\" role=\"tabpanel\"\u003e\n\u003cul\u003e\n\u003cli class=\"spec-title\"\u003e\n\u003ch5\u003eInput\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli class=\"spec\"\u003e12 to 24 volts AC or DC operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\"\u003e\n\u003ch5\u003eRelay\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli class=\"spec\"\u003eForm \"C\" relay contacts are rated 10A @120VAC\/28VDC.\u003c\/li\u003e\n\u003cli class=\"spec\"\u003eStandby current: 10mA (relay off) 50mA (relay on).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\"\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli class=\"spec\"\u003eEE Prom memory protects against loss of programming due to power failure.\u003c\/li\u003e\n\u003cli class=\"spec\"\u003eAccurate crystal controlled clock.\u003c\/li\u003e\n\u003cli class=\"spec\"\u003eMomentary and\/or Latching Events.\u003c\/li\u003e\n\u003cli class=\"spec\"\u003e50 individually programmed daily\/weekly events.\u003c\/li\u003e\n\u003cli class=\"spec\"\u003eBlock programming capacity can accommodate a total of 350 events per week.\u003c\/li\u003e\n\u003cli class=\"spec\"\u003e10 programmable Holiday dates.\u003c\/li\u003e\n\u003cli class=\"spec\"\u003e\"First man in\" option.\u003c\/li\u003e\n\u003cli class=\"spec\"\u003eStandard or Daylight Savings Time settings.\u003c\/li\u003e\n\u003cli class=\"spec\"\u003eAutomatic compensation for leap year.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\"\u003e\n\u003ch5\u003eVisual Indicators\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli class=\"spec\"\u003eAlphanumeric LCD display simplifies programming.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\"\u003e\n\u003ch5\u003eBattery Backup\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli class=\"spec\"\u003eBuilt-in charger for 12VDC sealed lead acid or gel type batteries(Max charge current 100mA).\u003c\/li\u003e\n\u003cli class=\"spec\"\u003eOptional lithium battery backup maintains clock.\u003c\/li\u003e\n\u003cli class=\"spec\"\u003eOrder Altronix part # LB2032.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\"\u003e\n\u003ch5\u003eTemperature\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli class=\"spec\"\u003eOperating -20ºC to 49ºC ( -4ºF to 120ºF).\u003c\/li\u003e\n\u003cli class=\"spec\"\u003eStorage -25ºC to 70ºC ( -13ºF to 158ºF).\u003c\/li\u003e\n\u003cli class=\"spec\"\u003eRelative Humidity 85% +\/- 5%.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Altronix","offers":[{"title":"Default Title","offer_id":40310961274965,"sku":"PT724A","price":113.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1102\/8096\/products\/PT724A.jpg?v=1663339910"},{"product_id":"altronix-al600ulacmcb-power-supply","title":"Altronix AL600ULACMCB Power Supply","description":"\u003cdiv class=\"row overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"well\" data-mce-fragment=\"1\"\u003e\n\u003cp class=\"text-left\" data-mce-fragment=\"1\"\u003eAltronix AL600ULACMCB converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and\/or Fail-Secure outputs with a total of 6A continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and\/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock \/ accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\" id=\"tab-container\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-md-6\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"row\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cul class=\"nav nav-tabs\" role=\"tablist\" id=\"prod-tabs\" data-mce-fragment=\"1\"\u003e\n\u003cli role=\"presentation\" class=\"active\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/AL600ULACMCB#specs\" aria-controls=\"specs\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/AL600ULACMCB#specs\"\u003eSpecifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/AL600ULACMCB#agency-listings\" aria-controls=\"agency-listings\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/AL600ULACMCB#agency-listings\"\u003eAgency Listings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/AL600ULACMCB#dimensions\" aria-controls=\"dimensions\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/AL600ULACMCB#dimensions\"\u003eDimensions \u0026amp; Weight\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/AL600ULACMCB#files\" aria-controls=\"files\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/AL600ULACMCB#files\"\u003e\u003ci class=\"icon-fontawesome-webfont-230\" data-mce-fragment=\"1\"\u003e\u003c\/i\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eDocumentation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"tab-content text-left\" id=\"prod-tabs-content\" data-mce-fragment=\"1\"\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"specs\" data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eInput\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eInput 115VAC 60Hz rated @ 3.5A.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003ePower supply input options:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ea) One (1) common power input for ACM8CB and lock power (factory installed).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eb) Two (2) isolated power inputs - One (1) to power the ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eEight (8) Access Control System trigger inputs.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eInput options:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ea) Eight (8) normally open (NO) inputs.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eb) Eight (8) open collector inputs.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ec) Any combination of the above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eOutput\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e12VDC or 24VDC @ 6A supply current.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eClass 2 Rated PTC protected power limited auto-resettable outputs.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eEight (8) independently controlled outputs.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eOutput options:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eEight (8) Fail-Safe and\/or Fail-Secure power outputs.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eEight (8) auxiliary power outputs (unswitched).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eOutput ratings\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ePTCs are rated @ 2.5A.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eFiltered and electronically regulated outputs (built-in power supply).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eACM8CB board main fuse is rated at 10A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eSupervision\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAC fail supervision (form \"C\" contacts).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eNotification trigger is selectable for 30 seconds (factory set) or 6 hours.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eLow battery and battery presence supervision (form \"C\" contact).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eFire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eFire Alarm disconnect input options:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ea) Normally open (NO) or normally closed (NC) dry contact input.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eb) Polarity reversal input from FACP signaling circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAlarm output relay indicates that FACP input is triggered (form \"C\" contact rated @ 1A 28VDC).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eShort circuit and thermal overload protection.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAC fail supervision (form \"C\" contact).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eVisual Indicators\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eRed LEDs indicate outputs are triggered (relays energized).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eGreen LED indicates FACP disconnect is triggered.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAC input and DC output LED indicators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eBattery Backup\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eBuilt-in charger for sealed lead acid or gel type batteries.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAutomatic switch over to stand-by battery when AC fails.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eZero voltage drop when unit switches over to battery backup (AC failure condition).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eBattery fail and battery presence supervision (form \"C\" contact).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eTemperature\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eOperating 0ºC to 49ºC (32ºF to 120ºF).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eStorage - 20ºC to 70ºC ( - 4ºF to 158ºF).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eRelative Humidity 85% +\/- 5%.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eBTU\/Hr. (approx.):\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e12VDC: 37 BTU\/Hr.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e24VDC: 74 BTU\/Hr.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Altronix","offers":[{"title":"Default Title","offer_id":40310970089557,"sku":"AL600ULACMCB","price":437.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1102\/8096\/products\/AL600ULACMCB.jpg?v=1663340275"},{"product_id":"altronix-al600ulacm-power-supply","title":"Altronix AL600ULACM Power Supply","description":"\u003cdiv class=\"row overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"well\" data-mce-fragment=\"1\"\u003e\n\u003cp class=\"text-left\" data-mce-fragment=\"1\"\u003eAltronix AL600ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and\/or Fail-Secure outputs with a total of 6A continuous supply current. These power outputs can be converted to dry form \"C\" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and\/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock \/ accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\" id=\"tab-container\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-md-6\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"row\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cul class=\"nav nav-tabs\" role=\"tablist\" id=\"prod-tabs\" data-mce-fragment=\"1\"\u003e\n\u003cli role=\"presentation\" class=\"active\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/AL600ULACM#specs\" aria-controls=\"specs\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/AL600ULACM#specs\"\u003eSpecifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/AL600ULACM#agency-listings\" aria-controls=\"agency-listings\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/AL600ULACM#agency-listings\"\u003eAgency Listings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/AL600ULACM#dimensions\" aria-controls=\"dimensions\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/AL600ULACM#dimensions\"\u003eDimensions \u0026amp; Weight\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/AL600ULACM#files\" aria-controls=\"files\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/AL600ULACM#files\"\u003e\u003ci class=\"icon-fontawesome-webfont-230\" data-mce-fragment=\"1\"\u003e\u003c\/i\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eDocumentation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"tab-content text-left\" id=\"prod-tabs-content\" data-mce-fragment=\"1\"\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"specs\" data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eInput\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eInput 115VAC 60Hz rated @ 3.5A.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003ePower supply input options:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ea) One (1) common power input for ACM8\/ACM8CB and lock power (factory installed).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eb) Two (2) isolated power inputs - One (1) to power the ACM8\/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eEight (8) Access Control System trigger inputs.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eInput options:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ea) Eight (8) normally open (NO) inputs.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eb) Eight (8) open collector inputs.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ec) Any combination of the above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eOutput\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e12VDC or 24VDC @ 6A supply current.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eEight (8) independently controlled outputs.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eOutput options:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ea) Eight (8) Fail-Safe and\/or Fail-Secure power outputs.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eb) Eight (8) form \"C\" 5A rated relay outputs\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ec) Any combination of the above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eEight (8) auxiliary power outputs (unswitched)\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eOutput ratings:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eFuses are rated @ 3.5A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eFiltered and electronically regulated outputs (built-in power supply).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eACM8 board main fuse is rated at 10A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eSupervision\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAC fail supervision (form \"C\" contacts).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eNotification trigger is selectable for 30 seconds (factory set) or 6 hours.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eLow battery and battery presence supervision (form \"C\" contact).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eFire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eFire Alarm disconnect input options:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ea) Normally open (NO) or normally closed (NC) dry contact input.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eb) Polarity reversal input from FACP signaling circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAlarm output relay indicates that FACP input is triggered (form \"C\" contact rated @ 1A 28VDC).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eShort circuit and thermal overload protection.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAC fail supervision (form \"C\" contact).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eVisual Indicators\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eRed LEDs indicate outputs are triggered (relays energized).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eGreen LED indicates FACP disconnect is triggered.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAC input and DC output LED indicators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eBattery Backup\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eBuilt-in charger for sealed lead acid or gel type batteries.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAutomatic switch over to stand-by battery when AC fails.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eZero voltage drop when unitswitches over to battery backup (AC failure condition).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eBattery fail and battery presence supervision (form \"C\" contact).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eTemperature\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eOperating: 0ºC to 49ºC (32ºF to 120ºF).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eStorage: - 20ºC to 70ºC ( - 4ºF to 158ºF).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eRelative Humidity 85% +\/- 5%.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eBTU\/Hr. (approx.):\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e12VDC: 37 BTU\/Hr.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e24VDC: 74 BTU\/Hr.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Altronix","offers":[{"title":"Default Title","offer_id":40310972710997,"sku":"","price":437.85,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1102\/8096\/products\/AL600ULACM.jpg?v=1663340443"},{"product_id":"altronix-r2416600ulcb-power-supply","title":"Altronix R2416600ULCB Power Supply","description":"\u003cdiv class=\"row overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"well\" data-mce-fragment=\"1\"\u003e\n\u003cp class=\"text-left\" data-mce-fragment=\"1\"\u003eR2416600ULCB provides 24VAC or 28VAC distributed via sixteen (16) PTC protected Class 2 Rated power limited outputs for powering CCTV cameras, heaters and other video accessories.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\" id=\"tab-container\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-md-6\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"row\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cul class=\"nav nav-tabs\" role=\"tablist\" id=\"prod-tabs\" data-mce-fragment=\"1\"\u003e\n\u003cli role=\"presentation\" class=\"active\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/R2416600ULCB#specs\" aria-controls=\"specs\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/R2416600ULCB#specs\"\u003eSpecifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/R2416600ULCB#agency-listings\" aria-controls=\"agency-listings\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/R2416600ULCB#agency-listings\"\u003eAgency Listings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/R2416600ULCB#dimensions\" aria-controls=\"dimensions\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/R2416600ULCB#dimensions\"\u003eDimensions \u0026amp; Weight\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/R2416600ULCB#files\" aria-controls=\"files\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/R2416600ULCB#files\"\u003e\u003ci class=\"icon-fontawesome-webfont-230\" data-mce-fragment=\"1\"\u003e\u003c\/i\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eDocumentation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"tab-content text-left\" id=\"prod-tabs-content\" data-mce-fragment=\"1\"\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"specs\" data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eInput\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e115VAC, 50\/60Hz, 6A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eOutput\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eSixteen (16) PTC protected Class 2 Rated power limited outputs (auto-resettable).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e24VAC @ 25A (600VA) supply current (0.7812A per device, 2.5A max.) or 28VAC @ 20A (560VA) supply current (0.625A per device, 2.5A max.).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eOutputs are rated @ 2.5A.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eSurge suppression.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eElectrical\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eTemperature:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eOperating: 0° C to 49° C (32° F to 120° F).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eStorage: - 20° C to 70° C ( - 4° F to 158° F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eRelative Humidity 85% +\/- 5%.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eBTU\/Hr (approx.):\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e24VDC: 307 BTU\/Hr.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e28VDC: 287 BTU\/Hr.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eSystem AC input VA requirement: 690VA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eSixteen (16) power LEDs.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eIlluminated master power disconnect circuit breaker with manual reset.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e3-wire grounded line cord.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eRemovable terminal blocks with locking screw flange.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Altronix","offers":[{"title":"Default Title","offer_id":40310980542549,"sku":"","price":595.35,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1102\/8096\/products\/R2416600ULCB.jpg?v=1663340793"},{"product_id":"altronix-al400ulxpd8-power-supply-charger","title":"Altronix AL400ULXPD8 Power Supply Charger","description":"\u003ch2 id=\"p-desc\" class=\"c-seclock-nickle\" data-mce-fragment=\"1\"\u003ePower Supply Charger, 8 Fused Outputs, 12\/24VDC @ 4A, 115VAC, BC400 Enclosure, AC Input and DC Output LED Indicator\u003c\/h2\u003e","brand":"Altronix","offers":[{"title":"Default Title","offer_id":40311014621269,"sku":"AL400ULXPD8","price":283.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1102\/8096\/products\/AL400ULXPD8.jpg?v=1663341116"},{"product_id":"altronix-fire-switch-108","title":"Altronix Fire Switch 108","description":"\u003cdiv class=\"section-header\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"row\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-sm-8 col-md-10 text-left\" data-mce-fragment=\"1\"\u003e\n\u003ch1 class=\"dark-text\" data-mce-fragment=\"1\"\u003eFireSwitch108\u003c\/h1\u003e\n\u003ch6 class=\"dark-text\" data-mce-fragment=\"1\"\u003eNAC Power Supply, 4 Class A, 8 Class B, 24VDC @ 10A, LCD and Network Connection for Programming and Status Monitoring, 115VAC, Red BC400 Enclosure\u003c\/h6\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4 col-md-2\" id=\"brand-logo\" data-mce-fragment=\"1\"\u003e\u003cimg id=\"brand-image\" src=\"https:\/\/www.altronix.com\/images\/brands\/icons\/fireswitch.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.altronix.com\/images\/brands\/icons\/fireswitch.jpg\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"well\" data-mce-fragment=\"1\"\u003e\n\u003cp class=\"text-left\" data-mce-fragment=\"1\"\u003eThe Altronix FireSwitch108 is a cost-effective managed NAC Power Extender. It interfaces with 12 or 24VDC Fire Alarm Control Panels (FACP) to provide Notification Appliance Circuit expansion support, for additional horns\/strobes to allow ADA compliancy. It also provides auxiliary power to support system accessories. It delivers electronically regulated and filtered 24VDC power to Class B or Class ANAC loop circuits. Alarm current can be divided between the eight (8) outputs for powering NAC devices. Outputs are rated at 2.5A max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). In non-alarm condition independent loop supervision for Class A and\/or Class B FACP NAC circuits is provided. In the event of a loop trouble, the FACP will be notified via the steered input (Input 1 or Input 2). In addition, there are common trouble output terminals [NC, C, NO] which are used to indicate general loop\/ system trouble. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the eight (8) outputs. It provides a programmable LCD display interface, plus an ethernet port interface for remote programmability and monitoring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\" id=\"tab-container\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-md-6\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"row\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cul class=\"nav nav-tabs\" role=\"tablist\" id=\"prod-tabs\" data-mce-fragment=\"1\"\u003e\n\u003cli role=\"presentation\" class=\"active\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/FireSwitch108#specs\" aria-controls=\"specs\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/FireSwitch108#specs\"\u003eSpecifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/FireSwitch108#agency-listings\" aria-controls=\"agency-listings\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/FireSwitch108#agency-listings\"\u003eAgency Listings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/FireSwitch108#dimensions\" aria-controls=\"dimensions\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/FireSwitch108#dimensions\"\u003eDimensions \u0026amp; Weight\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.altronix.com\/products\/FireSwitch108#files\" aria-controls=\"files\" role=\"tab\" data-toggle=\"tab\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.altronix.com\/products\/FireSwitch108#files\"\u003e\u003ci class=\"icon-fontawesome-webfont-230\" data-mce-fragment=\"1\"\u003e\u003c\/i\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eDocumentation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"tab-content text-left\" id=\"prod-tabs-content\" data-mce-fragment=\"1\"\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"specs\" data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eInput\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003ePower input: 120VAC, 60Hz, 4.8A.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eTwo (2) Class A or two (2) Class B FACP inputs.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eInput Ratings for - INP1 and INP2:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e8-30VDC 6.5mA max from FACP.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e12V 6.5mA, 24V 6.5mA from FACP.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eTwo (2) configurable inputs trigger via Class A or Class B FACP signal circuits (polarity reversal) or dry contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eOutputs\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eVoltage:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e24VDC regulated power-limited NACs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eOutput power:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e10A max. total alarm current.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e7A max. stand-by without battery back-up.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e1A with battery back-up including Aux. output (0.45A for Canadian applications).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e2.5A max current per output.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eOne (1) auxiliary output rated at 1A (regulated, battery backed up). 0.45A for Canadian applications.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAny NAC can be configured as an Aux. output with or without battery back-up (special application only). When set as Aux. output, the output is not supervised. Use UL Listed end of line device for the applications if supervision is required.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eProgrammable supervised indicating circuit outputs: Eight (8) Class B or Four (4) Class A, or any combination of Class A and Class B circuits.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eThermal and short circuit protection with auto reset.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eSupervision\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAC fail supervision (form “C” contact, 1A\/28VDC).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eBattery presence and low battery supervision (form “C” contact, 1A\/28VDC).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAC local dry contact output (form “C” contact, 1A\/28VDC).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eBattery Backup\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eBuilt-in charger for sealed lead acid or gel type batteries.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eAutomatic switchover to stand-by battery when AC fails.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eZero voltage drop when switching over to battery backup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eIndicators (LED)\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eLCD Display:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eIndicates trouble and conditions of operation\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eFacilitates quick identification of a fault.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eDisplays which output fault has occurred on.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eSpecial Features:\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eProgrammable LCD display interface.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eEOL resistor value is programmable by output.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eEthernet port interface for remote programmability and monitoring.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e2-wire horn\/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eSync protocols include Potter, Gentex®, System Sensor® , and CooperWheelock®.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eTemporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eCompatible with 12VDC or 24VDC fire panels.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eOutput loop supervision directed to input 1 or input 2.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eCommon trouble Dry N.C. output for reporting trouble to remote FACP.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eGround fault detection - Ground fault maximum test impedance 1,000 Ohm.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eGround fault Dry N.O. output to report ground fault to remote FACP.\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eCO Temporal Code 4 (NFPA720) include Gentex® , Potter and System Sensor® devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eTemperature\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eOperating: 0ºC to 49ºC (32ºF to 120ºF).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eStorage: - 20ºC to 70ºC ( - 4ºF to 158ºF).\u003c\/li\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003eRelative Humidity 85% +\/- 5%.\u003c\/li\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec-title\" data-mce-fragment=\"1\"\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eBTU\/Hr. (approx.):\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"spec\" data-mce-fragment=\"1\"\u003e123 BTU\/Hr.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Altronix","offers":[{"title":"Default Title","offer_id":40311020453973,"sku":"FIRE SWITCH 108","price":761.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1102\/8096\/products\/Fireswitch108.jpg?v=1663341468"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1102\/8096\/collections\/Altronix_b377a1ee-8f02-442f-a33e-ae097ec29538.jpg?v=1781620170","url":"https:\/\/uslocksupply.com\/collections\/altronix.oembed","provider":"US Lock Supply","version":"1.0","type":"link"}